Fire watch

Fire watch for construction sites and data centers

When the fire alarm is off, we are on – during construction and in live operations.

Fire safety assistants to DGUV-I 205-023 · Fire alarm & sprinkler · Gas suppression · 24h control room

When

The gap a fire watch closes

When a fire alarm or sprinkler system is switched off or fails, automatic fire detection is missing. A fire watch is then the required compensating measure.

Data hall fit-out

Detector lines switched off while dust and works would trigger false alarms.

Maintenance & modification

Fire alarm or sprinkler works in a live data center.

System failure

Short-notice cover when the fire alarm or sprinkler system is down.

Commissioning

Transition phases until all detectors are live.

Process

Covered in 4 steps

We know the process operators and general contractors must follow.

1

Agree the shutdown

Area, detector lines and time window agreed with site management and operator.

2

On site before shutdown

The fire watch is in place before the system is switched off.

3

Patrols & records

Continuous presence, rounds, complete records in the digital logbook.

4

Handover

Documented handover when the system is back in service.

Fire watch in a data hall during fit-outAccess control at full-height turnstilesOccupational paramedic on a data center construction site

Qualification

Qualified for the data center

Fire safety assistants

Trained to DGUV Information 205-023 and ASR A2.2.

Gas suppression

Briefed on extinguishing agents and conduct with gas suppression systems in data halls.

First aiders

All staff trained in first aid.

Full PPE

Helmet, glasses, hi-vis, gloves, safety boots.

Extinguishers on site

Suitable extinguishers always within reach.

24h control room

Direct escalation to fire brigade and site management.

Terms

Fire watch, fire post, fire safety watch

Three terms that are often confused.

Fire watch (Brandwache)

Monitors an area where automatic fire detection is switched off or has failed – our core deployment in data centers.

Fire post (Brandposten)

Covers a single hazard point directly, typically during and after hot works.

Fire safety watch (Brandsicherheitswache)

Required for events or by authority order and specified by the fire prevention office.

FAQ

Fire watch FAQ

When is a fire watch required?

Typically during hot works such as welding, cutting or soldering in fire-risk areas, when fire alarm or sprinkler systems are switched off or fail, and as a follow-up check after hot works. The basis includes German DGUV guidance 205-023 and the conditions in the hot work permit.

How long does a fire watch last?

For the duration of the works or for as long as the system is switched off. After hot works, a follow-up check is added, with its duration set in the permit.

What equipment does your fire watch have?

Suitable fire extinguishers, radio and phone, personal protective equipment and documentation of every patrol in the digital guard log.

How quickly can you provide a fire watch?

Planned deployments usually within 48 hours. For short-notice requests, please call us directly: +49 (0) 611 950 123 20.

Contact

Fire alarm going offline?

Fire watch on site at short notice – usually within 48 hours.

Sharif Jusufi, Managing Director

+49 (0) 611 950 123 20

Request fire watch